成人激情在线-国产剧情在线-精品不卡在线-美女又爽又黄网站视频-全部av―极品视觉盛宴-熟女少妇精品一区二区

咨詢熱線

010-68022247

當前位置:首頁  >  新聞中心  >  Fidas® Frog proves it worth at #MucOhneMief

Fidas® Frog proves it worth at #MucOhneMief

更新時間:2020-12-29      點擊次數:1449

 圖片2.png

Green City e.V. used the particle measurement system to collect well-founded data

The new Fidas® Frog has made an im- portant contribution to #MucOhne- Mief (meaning “Hashtag Munich with- out pong”), a campaign of the Munich-based environmental organi- zation Green City e.V. The compact monitoring system weighing only two kilograms simultaneously measures the particulate fractions PM1, PM2.5,

PM4 and PM10, as well as the particle size distributions, and is equipped with the TU?V-certified measurement tech- nology of the Fidas® 200. This enabled Green City e.V. to quickly and easily measure and evaluate particulate pol- lution at four different locations in Mu- nich for several weeks.

In Munich, this year the environmental or- ganization Green City e.V. launched the cam- paign #MucOhneMief (meaning “Hashtag Munich without pong”), intended to draw attention to the fine dust pollution in the city. The central element of the first phase of the campaign was the Fidas® Frog of Palas®, weighing only two kilograms. The fine dust monitoring system simultaneously measures the particulate fractions PM1, PM2.5, PM4 and PM10, as well as the particle size distributions and particle number concentrations. The handheld device is equipped with the sensors and evaluation routines of the Fidas® 200, which is TU?V-certified and approved by the Federal Environment Agency for measure- ments of the particle sizes PM2.5 and PM10. The environmental organization restricted the evaluation of the measurement results that it had collected for two months to these two particle sizes. Palas® provided the test device free of charge for this period.

Decisive advantages for the campaign were the lightweight, compact design of the Fidas® Frog and its ease of operation. Thus, with a de- vice Green City e.V. was able to collect well-founded data quickly and reliably at four different points in Munich’s Haidhausen quar- ter. Measurements were taken twice a day, in the morning and evening, for 20 minutes each per point. For this purpose, the measurement system was attached to a specially fitted bicy- cle at a height of approximately one meter. Stationary fine dust monitoring systems are of- ten installed at heights of 3 to 4 meters, where the burden is significantly lower. “We would deliberately take the measurements at a level where children’s noses are, and at times when children go to school. It was particularly im- portant to us to see the burden during this pe- riod”, explains Andreas Schuster, who is man- aging the campaign for Green City e.V.

On the occasion of the campaign start, Karsten Pletscher, Division Manager Environ- mental Monitoring at Palas®, was on site and explained the intuitive operation of the Fidas® Frog. The device is controlled via a detachable tablet. This enables users to actuate the con- trols even far off the measurement site. “Op- eration is child’s play. There are few parame- ters to be used during the measuring process. They are mastered after a single briefing and short personal use”, said Schuster. The func- tions for documentation and further process- ing of the measurement data did not present an obstacle to technical laypersons either.

圖片3.png 

High fine dust pollution in the matu- tinal hours

 The data were evaluated by Dr. Werner Zittel, Chairman of Ludwig-Bo?lkow-Stiftung, for Green City e.V. His analysis showed that fine dust pollution was very high especially in the morning. Here the annual average value for fine dust particles recommended by the WHO in Munich was exceeded at all four measure- ment points. Limits as those of the WHO relate to long-term and regular examinations. The measurementresultsobtainedwiththeFidas® Frog represent only a snapshot. Nevertheless, the data collected with the portable fine dust monitoring device are important arguments to support the #MucOhneMief campaign. They drew the desired media attention to the work of the environmental organization and sensi- tized many citizens to the problem of fine dust. “Our conclusion is that the public measure- ment stations in Munich are not sufficient to recordtheactualhazardtothecitizensona precise daily basis”, Schuster summarizes the measurement campaign with the Fidas® Frog.

主站蜘蛛池模板: 18禁美女裸体网站无遮挡| 日日碰狠狠添天天爽超碰97久久| 永久天堂网av手机版| 国产黑色丝袜在线播放| 欧美成a高清在线观看| 国产一区二区三区成人欧美日韩在线观看 | 2021年国产精品专区丝袜| 特黄特色大片免费播放器图片| 香港三级日本三级妇三级| 出租屋勾搭老熟妇啪啪| 亚洲成熟丰满熟妇高潮xxxxx | 少妇高潮喷水惨叫久久久久电影 | 亚洲一区二区三区影院| 成年午夜性影院免费观看| 色综合久久久久无码专区| 久久精品九九亚洲精品| 久久午夜羞羞影院免费观看| 九九久久精品国产免费看小说| 亚洲色欲或者高潮影院| 国产成人无码a区在线观看导航| 日韩一区二区三免费高清| 黑人猛挺进小莹的体内视频| 日韩在线aⅴ免费视频| 中文字幕成熟丰满人妻| 久久老子午夜精品无码怎么打| 麻豆果冻传媒精品一区| 九九久久精品无码专区| 综合自拍亚洲综合图区高清| 国产熟人av一二三区| 国产美女亚洲精品久久久99| 日本三级香港三级人妇99| 成人激情视| 无限看片在线版免费视频大全 | 娇妻在交换中哭喊着高潮| 国产特级毛片aaaaaaa高清| 果冻传媒mv免费播放在线观看| 欧美成人国产精品高潮| 不卡高清av手机在线观看| 欧美交换配乱吟粗大25p| 另类丅s人妖一区二区| 公与淑婷厨房猛烈进出视频免费|